SS... SN...
15: ROTARIES 216-535-4848
Sensors
The operating position can be checked by sensors (optional) that detect the inner magnet. Therefore, a nearby large mass of ferromagnetic material or intense magnetic fields may cause sensing troubles. Quick# Part# Signal Connection Price 3-wire, 90 Lead exit SN type Sensor 6278 SN4N225G PNP 2.5m lead $27.20 6357 SN4M225G NPN 2.5m lead $27.20 6277 SN3N203G PNP 0.3m lead with M8 male Connector $31.16 6356 SN3M203G NPN 0.3m lead with M8 male Connector $31.16 3-wire, Straight SS type Sensor 1882 SS4N225G PNP 2.5m lead $27.20 1883 SS4M225G NPN 2.5m lead $27.20 6282 SS3N203G PNP 0.3m lead with M8 male Connector $31.16 1884 SS3M203G NPN 0.3m lead with M8 male Connector $31.16
Swiveling Rotary - RT
Compressed air feeding
The compressed-air feeding must be accomplished on the lateral air ports (K) with fittings and hoses (not supplied). The compressed air must be filtered from 5 to 40m. Maintain the medium selected at the start, lubricated or not, for the complete service life of the swiveling unit. The pneumatic circuit must be pressurized progressively, to avoid uncontrolled movements.
Pneumatic circuit
Possible problems on a compressed air circuit: 1- Pressure variation 2- Pressurizing with empty cylinder 3- Sudden pressure black-out 4- Excessive speed Possible solutions: 1- Compressed air storage (A) 2- Start-up valve (B) 3- Safety valve (C) 4- Flow controller (D) Additional sensor can be placed in the sensor slots to detect the mid positions of the RTD.
803